А decoded
34 factory cable and wire codes in alphabetical order — with full names, catalogue sections and decoding.
F
- F/UTP Cat 5e PE Low-current cables · Low-current cables Decoding
- F/UTP Cat 5e PVC Low-current cables · Low-current cables Decoding
- F/UTP Cat 6 PE Low-current cables · Low-current cables Decoding
- F/UTP Cat 6 PVC Low-current cables · Low-current cables Decoding
- F/UTPт Cat 5e PE Low-current cables · Low-current cables Decoding
U
- U/UTP Cat 5e PE Low-current cables · Low-current cables Decoding
- U/UTP Cat 5e PVC Low-current cables · Low-current cables Decoding
- U/UTP Cat 6 PE Low-current cables · Low-current cables Decoding
- U/UTP Cat 6 PVC Low-current cables · Low-current cables Decoding
А
- А Bare aluminium conductor · Bare wires and wire rod Decoding
- АВБШв Armoured aluminium power cable · Armoured cables Decoding
- АВВГ Power cable with aluminium conductors · Power cables Decoding
- АВВГнг(А) Flame-retardant aluminium power cable · Power cables Decoding
- АПУНП Installation wires · Installation wires Decoding
- АС Steel-reinforced aluminium conductor · Bare wires and wire rod Decoding
В
К
П
- ПВС Flexible connecting wire · Flexible cables and cords Decoding
- ППГнг(А)-HF Halogen-free power cable · Power cables Decoding
- ПуВ Copper installation wire (solid conductor) · Installation wires Decoding
- ПуГВ Copper installation wire (flexible conductor) · Installation wires Decoding
- ПУГНП Flexible flat installation wire · Installation wires Decoding
- ПУНП Flat installation wire · Installation wires Decoding
С
Table of designations
Designations in cable and wire codes per GOST 31996, GOST 7399, GOST 839, GOST 31946 and ISO/IEC 11801. The same letter means different things in different positions — see the note under the letter.
Conductor
| А | Aluminium conductors |
|---|---|
| — | Copper conductors (no “A” at the start of the code) |
| ож / ок | Solid conductor (round / sector-shaped) |
| мк / мп | Stranded conductor (round / sector-shaped) |
| Г in a wire code | Flexible — highly flexible stranded conductor |
Insulation and sheath
| В | PVC insulation |
|---|---|
| П | Polyethylene insulation |
| Пв | Cross-linked polyethylene (XLPE) insulation |
| Р | Rubber insulation |
| П in ППГнг(А)-HF | Insulation of a halogen-free polymer compound |
| тп | Thermoplastic elastomer (TPE) insulation and sheath |
Protection and screen
| Г | No protective covering (unarmoured) |
|---|---|
| Б | Steel tape armour |
| Бб | Profiled steel tape armour |
| К after insulation — armour | Round steel wire armour |
| Шв | PVC outer protective sheath |
| Шп | Polyethylene outer protective sheath |
| Э | Screen |
Fire safety
| нг | Flame-retardant when installed singly |
|---|---|
| нг(А), нг(В), нг(С), нг(D) | Flame-retardant when bunched; the letter is the category (A is the strictest) |
| LS | Low smoke and gas emission when burning |
| HF | Halogen-free — no corrosive gases when burning |
| FR | Fire-resistant — keeps working in a fire for a set time |
| LTx | Low toxicity of combustion products |
Purpose and design
| К at the start of the code | Control cable |
|---|---|
| П at the start of the code | Wire |
| У, у | Installation wire — for fixed wiring |
| С in ПВС | Connecting — for connecting appliances |
| П at the end of the code | Flat |
| СИП | Self-supporting insulated wire for overhead lines |
Leave a request
We reply on working days from 9:00 to 18:00. A plant specialist will contact you directly.
+998 91 315 90 93 +998 99 808 51 71